Low Impedance Busbar Protection Panel Schematics

Learn from Professionals, Electrical Power Engineering

Udemy
platform
English
language
Engineering
category
Low Impedance Busbar Protection Panel Schematics
16
students
1 hour
content
Feb 2023
last update
$34.99
regular price

What you will learn

Introduction to busbar protection

Breaker Failure protection philosophy

Substation Single line diagram, shown for busbar protection logic

High impedance Vs Low impedance busbar protection, advantages and disadvantages of each protection

Breaker Failure stage 1 & 2 operation

Direct Transfer Trip in case of Breaker Failure protection stage 2

Busbar panel general characteristics

Design aspects of the panel

Explained the symbols used in the drawings

How busbar zone is formed

Line and busbar isolator

Busbar rating

What is isolator replica and why it is required

Selection of CT ratio criteria

Criteria for CT ratio selection

Option of CT ratio selection for low impedance busbar protection

Tripping matrix from busbar protection & breaker failure protection

Trip command from busbar protection based on the isolator replica

Basics of schematics, how page is divided in rows and column, how to read cross reference, move between pages.

How loop is defined in schematics & how loops are named

AC Supply circuit

AC supply change over scheme

Busbar protection blocking function, why it is required

Current transformer circuit of busbar protection

Power Supply circuit of busbar protection

Trip and Lockout schematics, CB Close Block, AR Block Schematics

Isolator Replica, CB faulty, DTT, Binary input Configurations

Direct Transfer Trip from Busbar

DC supply supervision Z sheet, component drawings, side and front view

Why take this course?

Dear All,

Welcome to the course about "Low Impedance Busbar Protection Panel Schematics". This training is start from very basic level to advance level. Focus has been given to deliver the practical and hands on knowledge.

Trainer have over 18 years of field experience and has worked at 11/132/220/500kV Substation, 1263MW power plant, 660kV HVDC system.  worked with several companies, SIEMENS, ABB, GE, SEC, KE, WAPDA, NTDC, ARAMCO, SABIC, MARAFIQ. Trainer has given hundreds of trainings online and offline, so it will be great to join this training and take advantage of field experience.

Following topics are covered in this training:

  • Introduction to busbar protection

  • Breaker Failure protection philosophy

  • Substation Single line diagram, shown for busbar protection logic

  • High impedance Vs Low impedance busbar protection, advantages and disadvantages of each protection

  • Breaker Failure stage 1 & 2 operation

  • Direct Transfer Trip in case of Breaker Failure protection stage 2

  • Busbar panel general characteristics

  • Design aspects of the panel

  • Explained the symbols used in the drawings

  • How busbar zone is formed

  • Line and busbar isolator

  • Busbar rating

  • What is isolator replica and why it is required

  • Criteria for  CT ratio selection

  • Option of CT ratio selection for low impedance busbar protection

  • Tripping matrix from busbar protection & breaker failure protection

  • Trip command from busbar protection based on the isolator replica

  • Basics of schematics, how page is divided in rows and column, how to read cross reference, move between pages.

  • How loop is defined in schematics & how loops are named

  • AC Supply circuit

  • AC supply change over scheme

  • Busbar protection blocking function, why it is required

  • Current transformer circuit of busbar protection

  • Power Supply circuit of busbar protection

  • Trip and Lockout schematics, CB Close Block, AR Block Schematics

  • Isolator Replica, CB faulty, DTT, Binary input Configurations

  • Direct Transfer Trip from Busbar

  • DC supply supervision

  • Z sheet, component drawings, side and front view

Thanks

Related Topics

5130204
udemy ID
2/1/2023
course created date
4/5/2023
course indexed date
Bot
course submited by